Skip to main content
JobDescription.orgSearch

Science

Medical Device Engineer Job Description

A Medical Device Engineer designs, tests and documents medical devices such as implants, surgical instruments, patient monitors and diagnostic systems, working inside a regulated design process that FDA can inspect. The role sits on research and development, design-transfer and sustaining teams at device manufacturers and at the contract design and test firms that serve them. BLS does not report the title separately. For the Engineers, All Other group employed in medical equipment and supplies manufacturing, May 2025 pay ran from $77,690 at the 10th percentile to $160,610 at the 90th, with a median of $108,590.

Last updated

Role at a glance

Typical education
Bachelor's degree in mechanical, electrical, biomedical, materials or chemical engineering.
Typical experience
As a rough guide, 5 to 8 years and one full product launch for senior titles.
Key certifications
Optional: NCEES FE exam, ASQ CQE or CMDA, RAPS Regulatory Affairs Certification (RAC-Devices).
Top employer types
Medical equipment and supplies manufacturers, electromedical instrument makers, and contract design and test firms.
Growth outlook
BLS does not report or project medical device engineers as a separate occupation.
AI impact (through 2030)
AI-enabled products add algorithm validation and change-control planning to the engineer's design file.

Duties and responsibilities

  • Write measurable design inputs from user needs and clinician feedback, assigning an acceptance criterion and a verification method to every requirement.
  • Build and update hazard analyses and design FMEAs, scoring severity and likelihood and tracing each risk control to a verification test.
  • Draft and run bench verification protocols for strength, fatigue, flow, electrical safety and packaging, then write reports tying results to requirements.
  • Plan simulated-use and human factors studies with clinicians and representative users to confirm the finished device meets its intended use.
  • Maintain the trace matrix linking user needs, design inputs, outputs, risk controls and test evidence so an auditor can follow any requirement.
  • Transfer released designs to manufacturing with drawings, inspection criteria and process validation support, then resolve issues found on the first production builds.
  • Assess engineering change orders for regulatory impact, updating the risk file and test plan and flagging changes that could need a new submission.
  • Investigate complaints and field returns with fault trees and fishbone diagrams, and feed confirmed fixes into the corrective and preventive action system.
  • Prepare device descriptions, test summaries and risk sections for 510(k), De Novo or PMA submissions, and answer FDA reviewer questions with data.
  • Qualify suppliers and components with purchasing and quality staff, reviewing material changes for effects on biocompatibility, sterilization compatibility and performance.

Overview

A Medical Device Engineer turns a clinical problem into a product that a hospital, clinic or patient can use safely, then proves it with test evidence a regulator will accept. The work happens at manufacturers of implants, catheters, surgical instruments, infusion pumps, patient monitors, imaging systems and diagnostic analyzers, and at the contract design and test firms that serve them. The engineering discipline changes with the product: a stent program needs materials and fatigue specialists, a bedside monitor needs electrical and firmware engineers, and a reusable surgical tool needs someone who understands cleaning and sterilization. What ties the title together is the regulated design file that every one of those engineers contributes to.

A program starts with design inputs. The engineer turns user needs into measurable requirements: insertion force, battery runtime, accuracy at the edge of the measuring range, resistance to a hospital disinfectant wipe. Each requirement gets a verification method before any testing starts, and each later design output has to trace back to an input. When a requirement moves, the trace matrix, the risk file and the test plan move with it.

Risk analysis runs alongside the design rather than after it. Engineers build hazard analyses and design failure modes and effects analyses (DFMEAs), score severity and likelihood, and choose controls that can themselves be tested. On any product with software or a network port, a security risk assessment sits next to the safety one, and FDA treats security risk management as a separate process from the safety risk management described in ISO 14971.

Verification and validation fill the middle of a program. Bench verification checks outputs against inputs: tensile pulls, flow rates, electrical safety, accelerated aging of sterile packaging, drop and vibration tests for shipping. Validation asks a different question, whether the finished device meets user needs in conditions close to real use, which can mean simulated-use sessions with surgeons or nurses and human factors testing with representative users.

Design transfer comes next. The engineer hands manufacturing a package of drawings, specifications, inspection criteria and process validation support that a production line can repeat shift after shift. Sustaining engineering is its own track after launch: running engineering change orders, working complaint investigations, qualifying a second-source component, or judging whether a supplier's resin change calls for new biocompatibility testing.

Submission support is the last major thread. Engineers write the device description, test summaries and risk sections for a 510(k), De Novo request or premarket approval application, then answer the agency's follow-up questions with data rather than argument.

The job rewards people who like physics and paperwork in equal measure. A clever design that cannot be verified, or a passing test that was never planned in advance, will not hold up in an inspection or a reviewer's deficiency letter. The engineers who do well write requirements a stranger could test against and keep records a stranger could audit.

Qualifications

As a rough guide, the entry point is a bachelor's degree in mechanical, electrical, biomedical, materials or chemical engineering. For a related BLS occupation, bioengineers and biomedical engineers, the agency lists a bachelor's degree as the typical entry-level education. A graduate degree carries more weight on research-heavy programs such as neural interfaces, imaging physics or tissue-contacting materials, and some engineers add one part-time once they know which product area they want to stay in.

School covers the physics. The regulated half of the job is learned at work, and a good hiring manager will probe it directly. A candidate should be able to explain:

  • How a design input becomes a verified output, and what a trace matrix shows an auditor.
  • How a hazard analysis differs from a DFMEA, and how a risk control is itself verified.
  • What makes a test protocol valid: acceptance criteria and sample size fixed before the test runs.
  • How a proposed change is screened for regulatory impact, including whether it could need a new 510(k).
  • How the clause structure of ISO 13485 shows up in the company's own procedures.

Technical skills follow the product. Mechanical engineers work in CAD tools such as SolidWorks, Creo or NX, apply GD&T, run tolerance stack-ups and finite element models, and use Minitab or JMP for sample sizes and process capability. Electrical engineers handle schematic capture, board bring-up, and electrical safety and electromagnetic compatibility testing. Software and firmware engineers write embedded C or C++, maintain requirements in a tool such as Jama or Polarion, run static analysis, and on connected products keep the threat model and the software component list current.

As a rough guide, senior titles tend to come after 5 to 8 years and at least one product carried from design inputs through launch. Credentials are optional, but each fits a particular direction:

  • Fundamentals of Engineering (FE) exam from NCEES, generally the first step for an engineer who may later seek a Professional Engineer license from a state board.
  • Certified Quality Engineer (CQE) and Certified Medical Device Auditor (CMDA), both from ASQ, for engineers moving toward quality or audit work.
  • Regulatory Affairs Certification for medical devices (RAC-Devices) from the Regulatory Affairs Professionals Society, for engineers shifting toward submission strategy.

The habits that separate strong candidates are plain ones. They write test reports a reviewer can follow without a phone call, they document a rationale at the time a decision is made, and they treat a failed test as data to explain rather than a result to rerun quietly.

Career outlook

BLS does not report medical device engineers as a separate occupation, so the clearest view of the field comes from its industry tables. In the May 2025 survey, BLS counted 1,130 workers in the Engineers, All Other group employed in medical equipment and supplies manufacturing. The same industry employed 3,080 mechanical engineers, 2,460 bioengineers and biomedical engineers, and 620 electrical engineers. A device team in that industry can include engineers from every one of those occupations, each owning a different part of the same design file.

Pay inside that industry varies by occupation. The May 2025 median was $104,950 for mechanical engineers, $107,550 for bioengineers and biomedical engineers, and $128,460 for electrical engineers working in medical equipment and supplies manufacturing.

FDA's Quality Management System Regulation took effect on February 2, 2026, and it reaches straight into design work. FDA says the rule now specifically requires risk management. On the same date the agency stopped using its Quality System Inspection Technique (QSIT) for device inspections and began inspecting under Compliance Program 7382.850. The rule also removed an old shelter: FDA says the QMSR gives it authority to inspect management review, quality audits and supplier audit reports, records that the previous regulation exempted. FDA also states that devices made under an investigational device exemption are not exempt from design and development requirements, so engineers on early clinical builds work under those controls too.

Connected products carry a second set of obligations. Section 524B of the FD&C Act took effect on March 29, 2023 for premarket submissions for cyber devices. FDA reissued its cybersecurity guidance on February 3, 2026, superseding the version issued June 27, 2025. The guidance covers threat modeling and says a secure product development framework may be one way to satisfy the QMSR. It also notes that section 524B(b)(3) requires manufacturers of cyber devices to provide a software bill of materials, including commercial, open-source and off-the-shelf software components. For a firmware engineer, that is a parts list for code, kept under change control like the hardware bill of materials.

Career paths branch after the first few products. The technical track runs toward principal or staff engineer, the owner of architecture decisions across a product family. Others move into engineering management, quality engineering, regulatory affairs or clinical engineering inside a health system. Each of those moves draws on the same core skill: knowing what evidence a design decision needs and how to produce it.

For a job seeker, the practical advice is to collect proof of shipped work. A verification report you wrote, a risk file you maintained, a change order you pushed through review or a submission section you drafted tells a hiring panel more than a list of software packages. Engineers who can also speak to cybersecurity documentation or ISO 13485 procedures are ready for the questions an inspector working under the new program may ask.

Sample cover letter

Dear Hiring Manager,

I am applying for the Medical Device Engineer opening on your vascular access team. For the past five years I have worked as a design engineer at a mid-size catheter manufacturer, splitting my time between a new peripheral catheter platform and sustaining work on two legacy product lines.

On the new platform I owned the design inputs for the hub and strain relief. I wrote the requirements from clinician interviews and bench observations, set acceptance criteria with our quality engineer before any testing began, and ran the DFMEA sessions with manufacturing and regulatory in the room. When a kink-resistance test failed late in verification, I traced the cause to a wall-thickness tolerance we had carried over from an older drawing. I reopened the requirement, updated the risk file, and reran the test under a revised protocol, and the change record shows each step.

My sustaining work taught me the other half of the job. I have run change orders for a supplier resin substitution and a packaging redesign, and I learned to ask early whether a change touches biocompatibility, sterilization or labeling, because those questions decide the schedule. I also wrote the test summary sections for one 510(k) and answered the reviewer's follow-up questions with new data.

Your team's move into connected infusion accessories interests me because it would add firmware and cybersecurity work to the mechanical design I already know. I have started building that skill by working with our software group on its threat model and software component list, and I would like to keep growing in that direction.

I would welcome the chance to walk you through my verification reports and change records.

Sincerely, Jordan Ellison

Frequently asked questions

What does a Medical Device Engineer do?
A Medical Device Engineer designs, tests and documents medical devices such as implants, surgical instruments, patient monitors and diagnostic systems, working inside a regulated design process that FDA can inspect. The role sits on research and development, design-transfer and sustaining teams at device manufacturers and at the contract design and test firms that serve them. BLS does not report the title separately. For the Engineers, All Other group employed in medical equipment and supplies manufacturing, May 2025 pay ran from $77,690 at the 10th percentile to $160,610 at the 90th, with a median of $108,590.
What are the main duties of a Medical Device Engineer?
Core duties include: write measurable design inputs from user needs and clinician feedback, assigning an acceptance criterion and a verification method to every requirement; build and update hazard analyses and design FMEAs, scoring severity and likelihood and tracing each risk control to a verification test; and draft and run bench verification protocols for strength, fatigue, flow, electrical safety and packaging, then write reports tying results to requirements.
How does a Medical Device Engineer prepare an FDA 510(k) or De Novo submission?
The engineer supplies the technical core: device description, verification and validation summaries, risk analysis and the test reports behind them. FDA requires eSTAR, an interactive PDF form that guides applicants through the submission, for all 510(k) and De Novo submissions to CDRH or CBER unless exempted, so test reports have to map cleanly onto its sections.
How is AI changing work for device engineers?
On AI-enabled products, FDA's final guidance on predetermined change control plans recommends that a plan describe the planned device modifications, the methodology to develop, validate and implement them, and an assessment of their impact. FDA's January 2025 guidance on lifecycle management for AI-enabled device software functions is still listed as a draft. FDA reviews a PCCP as part of the marketing submission, so the planning for later algorithm changes is engineering work done before the device is authorized for marketing.
Is a medical device engineer the same as a biomedical engineer?
Not exactly. BLS says bioengineers and biomedical engineers design equipment and devices such as artificial internal organs, replacements for body parts and machines for diagnosing medical problems, which overlaps heavily with device design. The device title, though, is also held by mechanical, electrical, software and materials engineers whose degrees never mention biology.
What is the difference between design verification and design validation?
Verification asks whether the design outputs meet the design inputs, usually through bench tests against written acceptance criteria. Validation asks whether the finished device meets user needs and its intended use, often through simulated-use or human factors testing with representative users on production-equivalent units.
What does a sustaining engineer do on a device team?
A sustaining engineer keeps a product that is already on the market safe, buildable and compliant. The work covers engineering change orders, complaint and field-return investigations, obsolete or second-source component qualifications, and supplier material changes, each assessed against the existing risk file and test record.

Sources

Salary figures and role details on this page were checked against the following sources. Dates show when each was last reviewed.

  1. Medical Equipment and Supplies Manufacturing (NAICS 339100) industry-specific estimates, BLS Occupational Employment and Wage Statistics (May 2025)Checked Nov 10, 2026
  2. Engineers, All Other, BLS Occupational Employment and Wage Statistics (May 2025)Checked Nov 10, 2026
  3. O*NET 30.3 Database, Job Titles file, National Center for O*NET DevelopmentChecked Nov 10, 2026
  4. Quality Management System Regulation (QMSR), U.S. Food and Drug Administration (updated February 2, 2026)Checked Nov 10, 2026
  5. Quality Management System Regulation: Frequently Asked Questions, U.S. Food and Drug Administration (February 2, 2026)Checked Nov 10, 2026
  6. Cybersecurity in Medical Devices: Quality Management System Considerations and Content of Premarket Submissions, final guidance, U.S. Food and Drug Administration (February 3, 2026)Checked Nov 10, 2026
  7. eSTAR Program, U.S. Food and Drug Administration (2026)Checked Nov 10, 2026
  8. Marketing Submission Recommendations for a Predetermined Change Control Plan for Artificial Intelligence-Enabled Device Software Functions, final guidance, U.S. Food and Drug Administration (August 2025)Checked Nov 10, 2026
  9. Artificial Intelligence-Enabled Device Software Functions: Lifecycle Management and Marketing Submission Recommendations, draft guidance, U.S. Food and Drug Administration (January 2025)Checked Nov 10, 2026
  10. Bioengineers and Biomedical Engineers, Occupational Outlook Handbook, U.S. Bureau of Labor StatisticsChecked Nov 10, 2026
  11. Fundamentals of Engineering (FE) Exam, NCEES (2026)Checked Nov 10, 2026
  12. Certified Quality Engineer (CQE) Certification, ASQ (2026)Checked Nov 10, 2026
  13. Regulatory Affairs Certification (RAC), Regulatory Affairs Professionals Society (2026)Checked Nov 10, 2026
See all Science jobs →